::. ELECTRICAL :..Digital Earth Tester..:

DUST AND DRIP PROOF (DESIGNED TO IEC60529 IP54)

In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories. ( unit can be hung from the neck for simplified measurement)
Designed to meet IEC61010-1, IEC61557 safety standard. Capable of measuring earth voltage. Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance. 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.

SPECIFICATIONS
Measurement Ranges Earth Resistance:0-20Ω/0-200Ω/0-2000Ω
Earth Voltage(50-60Hz):0-200V AC
Safety Standard IEC61010-1 CAT.300V Pollution Degree 2, IEC61557
Applicable Standards IEC60529 IP54
Dimensions 105(L)158(W)70(D)mm

 
::. ELECTRICAL :..Digital Power Clamp Meter..:

The new Megger DCM2000P Power Clamp meter combines the functionality of power meter, oscilloscope, harmonics meter and data logger in one easy to use package. The design meets the requirements of BSEN 61010-1 600V Cat IV for supply side applications. A large backlit dot matrix LCD clearly displays waveforms, harmonics chart trends and up to 5 parameters at a time. The DCM2000P Can measure DC, AC, pulsed and mixed currents up to 2000 A, Voltage up to 600 V, all power related parameters including energy consumption, frequency, crest factor, total harmonic distortion, distortion factor and ripple. It features auto-ranging and auto-zeroing and has a buit-in-3 phase adapter for power measurements. This battery-operated precision power meter can transmit both stored and live measurements to a PC running power log software for further analysis if required. The DCM2000P is ideally suited to measuring mains power quality and applications in the development, installation, maintenance and repair of equipment and devices used in power electronics and power engineering. It simplifies the compensation of reactive power, even for complex waveforms with high harmonic distortion.

W, VA, VAR, KWh And power factor me asurement even on distorted waveforms
AC/DC Current up to 2000Amps
True rms, peak, crest factor, THD, DF, Frequency measurement and DC Ripple
3 Phase power capability
Live Harmonic Analysis, barograph display

 
::. ELECTRICAL :..Industrial Insulation Tester ..:
Specifications
CATIV 600 V applications
Insulation testing to 1000 V and to 200 G Ω
TRMS & DC voltage measurement
Continuity testing at 200 mA down to 0.01 Ω
Analogue and dual digital display
Insulation & continuity limit alarms
PI/DAR and timer function
Test result storage
Bluetooth wireless data transfer
Calibration certificate included

 
 
::. ELECTRICAL :..Automatic Oil Test Sets ..:
Specifications
Microprocessor controlled fully automatic oil test sets
Wide choice of vessels and accessories

Description

The Megger range of automatic oil testers offer fully automatic testing with many advanced features. The design allows operator to simply prepare an oil test vessel, load it with the sample oil, place it in the chamber and initiate the test sequence. The test set then carries out, the series of tests as specified in large number of oil testing specifications. These define the sequence of tests including the stand and stir times, rate of voltage rise and number of tests resulting in a calculation of the average value of the oil breakdown strength. Withstand or proof testing can also be selected. This test subjects the oil to a pre selected voltage for 1 minute to check for a breakdown.


 
::. ELECTRICAL :..Others..:
Also look out for
Relay Test Equipment
Cable fault locator
 
^0
 
 